Product description
After each use, the plug valve should be thoroughly rinsed with clean water to remove any corrosivesubstances
such as cement or acidic substances remaining inside the valve. Then, high-pressure
airshould be used to dry the water stains to prevent corrosion of the inner surface and seals;
After each use, with the valve open, use a high-pressure grease gun to refill the valve with new
sealing grease for the plug valve. After squeezing out all the old sealing grease, open and close
the valve multiple times to ensure that the new sealing grease evenly covers the valve interior,
plug valve, and sealing arc surface;
The exposed threads on the plug valve should be coated with anti rust oil and fitted with corresponding
thread protection sleeves to prevent rusting or damage when not in use;
Check and replace the damaged grease valve to ensure proper lubrication of the valve body.